XMC and PMC I/O and Counter/Timer Modules
RedLinX™ offers a variety of add-on I/O and counter/timer daughterboards in the form of XMC (VITA 42.0) and PMC (IEEE P1386.1) modules.
| PMC230 | PMC 16-Bit D/A Analog Output |
| PMC330 | PMC Analog Input Module, 16-bit A/D |
| PMC341 | PMC Analog Input Module, Simultaneous Sample & Hold |
| PMC408 | PMC Digital Input/Output Module, High Voltage I/O |
| PMC424 | PMC Digital Input/Output Module, Differential, TTL, Counter/Timer |
| PMC464 | PMC Digital I/O Module, Counter/Timer |
| PMC730 | PMC Multi-Function I/O Board (A/D, D/A, Digital I/O, Counter/Timer) |
| PMC482 | PMC Counter/Timer Module |
| PMC483 | PMC Counter/Timer Module |
| PMC484 | PMC Counter/Timer Module |
Click here for a catalogue of all Acromag products (7 MB download).
This is an illustative sample of the products we have available. Feel free to contact us at sales@redlinx·co·za for information on more options to meet your requirements.
PMC230: PMC 16-Bit D/A Analog Output
Key features:
- 8 analog voltage output channels
- Individual 16-bit D/A converters per channel
- 10µS settling time (100KHz throughput)
- Three output ranges: ±5V, ±10V, 0 to 10V (jumper-selectable)
- Two trigger modes (software or external trigger)
- External trigger output
- High load capability (5mA output current)
- 0°C to 70°C (PMC230-8) or -40°C to 85°C (PMC230-8E model)
PMC330: PMC Analog Input Module, 16-bit A/D
Key features:
- 16-bit A/D converter (ADC)
- 8µS conversion time (125KHz)
- 16 differential or 32 single-ended inputs (±5V, ±10V, 0-5V, and 0-10V input ranges)
- Individual channel mailbox with one or two storage buffer registers per channel
- Programmable scan control
- Four scanning modes
- User-programmable interval timer
- External trigger input and output
- Programmable gain for individual channels
- Post-conversion interrupts
- 0°C to 70°C (PMC330) or -40°C to 85°C (PMC330E model)
PMC341: PMC Analog Input Module, Simultaneous Sample & Hold
Key features:
- 16 differential inputs (±10V DC input range)
- Eight 14-bit A/D converters with simultaneous sample and hold capability
- 8µS conversion time (125KHz) for 8-channel bank
- Two 512-sample memory buffers
- Data tagging for channel identification
- Programmable conversion timer
- Programmable channel conversion control
- External trigger input and output
- Continuous and single-cycle conversion modes
- Interrupt generation for memory full threshold conditions
- Precision calibration voltages stored on-board
- 0°C to 70°C (PMC341) or -40°C to 85°C (PMC341E model)
PMC408: PMC Digital Input/Output Module, High Voltage I/O
Key features:
- 32 digital input and/or output channels
- 0 to 60V DC input range, 60V DC low-side switch outputs
- Outputs sink up to 1A per channel
- TTL-compatible input threshold with hysteresis
- Change-of-state/level interrupts (up to 8)
- 0°C to 70°C or -40°C to 85°C (E version)
PMC424: PMC Digital Input/Output Module, Differential, TTL, Counter/Timer
Key features:
- Digital I/O
- 40 digital input/output channels:
- 24 differential input/outputs
- 16 TTL input/output channels (15 ch. for 434R)
- Programmable change of state/level interrupts
- Input signal filtering debounce logic
- Counter/Timer
- Four 16-bit or two 32-bit counter/timer channels (control lines shared with 16 TTL I/O channels)
- Six operating modes:
- Pulse width modulation
- Watchdog timer
- Event counter
- Frequency measurement
- Pulse width or period measurement
- One-shot and repetitive one-shot
- TTL-compatible thresholds
- Power-up and system reset are failsafe
- 0°C to 70°C (PMC424 / R) or -40°C to 85°C (PMC424E / CC)
PMC464: PMC Digital I/O Module, Counter/Timer
Key features:
- Digital I/O
- 64 digital input/output channels:
- 16 individually programmable channels
- 48 channels configured on an 8-bit port basis
- Programmable change of state/level interrupts
- Input signal filtering debounce logic
- Counter/Timer
- Four 16-bit counter/timer channels (alternatively configurable as two 32-bit counter/timers)
- Six operating modes:
- Pulse width modulation
- Watchdog timer
- Event counter
- Frequency measurement
- Pulse width or period measurement
- One-shot and repetitive one-shot
- TTL-compatible thresholds
- Power-up and system reset is failsafe
- 0°C to 70°C (PMC464 / R) or -40°C to 85°C (PMC464E / CC)
PMC730: PMC Multi-Function I/O Board (A/D, D/A, Digital I/O, Counter/Timer)
Key features:
- Analog Inputs
- 16 differential or 32 single-ended inputs (±3.3V, ±5V, ±10V, 0-5V, and 0-10V ranges)
- 16-bit ADC with 512 sample RAM
- 10µS conversion time (100KHz)
- Interrupt upon ADC memory threshold condition (user-programmable data sample threshold)
- User-programmable interval timer
- Analog Outputs
- Eight analog output channels (±10V range)
- Individual 16-bit DACs per channel
- 1024 sample FIFO for waverform generation
- 12.375µS settling time (80.8KHz throughput)
- Interrupt on user-programmable FIFO threshold
- Digital I/O & Counter/Timers
- 16 TTL bidirectional input/outputs
- One 32-bit counter/timer
- 0°C to 70°C (PMC730 / R) or -40°C to 85°C (PMC730E / CC)
PMC482: PMC Counter/Timer Module
Key features:
- Ten 16-bit counter/timers
- Two 16-bit counters can be combined to create one 32-bit counter
- 16 bi-directional digital I/O
- 20MHz clock time base
- Single counter/timer modes:
- Event counting
- Frequency measurement
- Period/pulse-width measurement
- Quadrature position measurement
- Square wave/pulse train generation
- Time/period interrupter
- 32-bit counter/timer
- Pulse width generation
- 0°C to 70°C or -40°C to 85°C (E version)
PMC483: PMC Counter/Timer Module
Key features:
- Four 16-bit counters – TTL, and Four 32-bit counters – RS422
- Two 16-bit counters can be combined to create one 32-bit counter
- 16 bi-directional digital I/O
- 20MHz clock time base
- Single counter/timer modes:
- Event counting
- Frequency measurement
- Period/pulse-width measurement
- Quadrature position measurement
- Square wave/pulse train generation
- Time/period interrupter
- 32-bit counter/timer
- Pulse width generation
- 0°C to 70°C or -40°C to 85°C (E version)
PMC484: PMC Counter/Timer Module
Key features:
- Six 32-bit counter/timers
- 16 bi-directional digital I/O
- 20MHz clock time base
- Single counter/timer modes:
- Event counting
- Frequency measurement
- Period/pulse-width measurement
- Quadrature position measurement
- Square wave/pulse train generation
- Time/period interrupter
- 32-bit counter/timer
- Pulse width generation
- 0°C to 70°C or -40°C to 85°C (E version)
Back to top